ICD-001 Status Report

Introduction

This page covers the ICD-001 Status Report.

Contents



Example Status Report

<?xml version="1.0" encoding="utf-8"?> <StatusReport xmlns="ICDNAV001-StatusReport" StatusId="23232"> <Sender SenderId="SenderId1" NetworkAddress="127.0.0.1" NetworkPort="6317" /> <ModuleStatus Reported="2019-04-03T22:05:02.112" Name="Management Server" Status="Online" ModuleId="3dc5d6e3-5bda-4625-bdef-6d6ecef363c2" ModuleType="ManagementServer"> <Health Type="Database" MinValue="0" MaxValue="0" Value="0" Status="Warning" /> </ModuleStatus> <!-- Module Track Engine 1 is offline --> <ModuleStatus Name="TE1" Reported="2019-04-03T22:05:02.112" Status="Offline" ModuleId="710e8979-effb-4d2d-94d4-205aa4bd0eae" /> <ModuleStatus Name="TE2" Reported="2019-04-03T22:05:02.112" Status="Online" ModuleId="C565AE57-95C5-4C17-8CF3-E19609067500" /> <ModuleStatus Name="Camera Controller" Reported="2019-04-03T22:05:02.112" Status="Online" ModuleId="AF648F4D-3342-406E-888A-F4FAD05B36AA"/> <!-- Radar 1 being reported as offline - therefore no health metric can be reported --> <RadarHealth RadarId="1" Name="Radar 1" Reported="2019-04-03T22:05:02.112" Packets="0" Temp="0" Rotation="0" Status="Offline" /> <!-- Radar 2 being reported with a connection status of warning meaning a temporary loss of connection to the radar --> <RadarHealth RadarId="2" Name="Radar 2" Reported="2019-04-03T22:05:02.112" Packets="801" Temp="85" Rotation="2.0" Status="Warning" /> <!-- Radar 3 being reported as online but with a warning status because the temperature is too low --> <RadarHealth RadarId="3" Name="Radar 3" Reported="2019-04-03T22:05:02.112" Packets="1600" Temp="59" Rotation="4.01" Status="Online" HealthStatus="Warning"> <Health Type="Temperature" MinValue="-20" MaxValue="90" Value="-22" Status="Warning" xmlns="ICDNAV001-CommonTypes" /> </RadarHealth> <!-- The current system profile is the set to the default --> <SystemProfileStatus Name="Default" ProfileId="-1" Reported="2019-04-03T22:05:02.112" /> <AreaSummary Reported="2019-04-03T22:05:02.112"> <AreaStatus Type="General" Name="Front Gate" AreaId="1" Enabled="Enabled" /> <AreaStatus Type="Detection" Name="Detection North" AreaId="2" Enabled="Enabled" /> <AreaStatus Type="Alarm" Name="Alarm Zone A" AreaId="3" Enabled="Disabled" /> </AreaSummary> </StatusReport>

Status Report Element

The status report element has an optional StatusId attribute that will increment with every status report

Attribute 

Description

Type

Unit

StatusId

Incrementing Id of the status report

Long

 

Module Status Element

The module status is essentially a heartbeat. Each module typically sends a heartbeat message every 5 seconds. For each module, assuming a heartbeat has been received, a status element will be added to the status report. If a status element is not present, then either the heartbeat has been delayed or the module has gone offline. When requesting a status report using a Command Message, the report can be filtered to only include the Module and Radar Health Status.

Module Status Attributes

Optional attributes are formatted in italics and highlighted with an asterisk.

Attribute 

Description

Type

Unit

Name

Name of the module.

String

 

Reported

Time status was reported.

DateTime

 

Status

Status of module connection – options are:·        

Online

Warning

Offline

ConnectionStatusTypeList

 

ModuleId*

Unique identifier for the module (optional).

String (representation of a GUID / UUID)



ModuleType*

Module type (optional). This is available in Witness 4.0 and higher.

String



HostIP*

IP of the server hosting the module (optional). This is available in Witness 4.0 and higher.

String



Module Status Health Element (Optional)

Health elements of module status will only appear if the health elements are not heathy

Attribute

Description

Type

Unit

Attribute

Description

Type

Unit

Type

Type of Health - options are:

Database

HealthInfoTypeList

 

Status

Health Status - options are:

Unknown

Healthy

Warning

Unhealthy

HealthStatusTypeList

 

MinValue

Not used

Double

 

MaxValue

Not used

Double

 

Value

Not used

Double

 

Radar Health Element

The radar health element provides specific health details for each sensor in the system. If a radar is active and connected then the Witness system will receive regular health updates. The latest health report for each radar is added to the status report. If a recent health update has not been received for any of the radar then there will be no element for that radar.

Radar Health Attributes

Attribute

Description

Type

Unit

RadarId

ID of the radar

Long

 

Name*

User-friendly name of the radar (optional)

String

 

Reported

Time health was reported

DateTime



Packets

Radar packet rate per second. Value will vary depending on the range and mode of the radar

Double



Temp

The current operating temperature of the sensor

Double

 

Rotation

The current rotation rate of the radar. Some models of radar have different rotation speeds but the default is 1Hz.

Double



Status

Status of radar connection – options are:

Online

Warning

Offline

ConnectionStatusTypeList



HealthStatus

Health Status of Radar - options are:

Unknown

Healthy

Warning

Unhealthy

If Status of radar is Offline then the health status will be Unknown.

HealthStatusTypeList

 

Radar Health Status Element (Optional)

Radar health status items will only appear if the Radar has a HealthStatus of Warning or Unhealthy

Attribute

Description

Type

Unit

Attribute

Description

Type

Unit

Type

Type of Health - options are:

Temperature

PacketRate

Rotation

RxPacketRate

MotorCurrent

EncoderErrors

ClutterFloor

HealthInfoTypeList

 

Status

Health Status - options are:

Unknown

Healthy

Warning

Unhealthy

HealthStatusTypeList

 

MinValue

Minimum value can be

Double

 

MaxValue

Maximum value can be

Double

 

Value

Value

Double

 

If a module or radar is removed from the list, then this would indicate the device has been shut down intentionally (i.e. a user stops a Bloodhound service) and should not be a cause for concern. In this situation the health will stop being reported for the removed device.

There is no status to indicate that any of the values contained within the health data are outside expected parameters. This checking should be performed by the 3rd party based on suitable criteria for their own application. 

Be aware that radar health can only be reported if the tracker is active. If a tracker goes offline, then no radar health will be reported for that tracker. 

Trackers and their attached radar will always share the same Id (i.e. tracker ID:1 will be connected to radar ID:1). 

System Profile Status Element

The system status element shows which system profile is currently active. The Id is the UserId of the profile and the name is also included to make the data more readable. When requesting a status report using a Command Message, the report can be filtered to only include the System Profile Status.

System Profile Status Attributes

Attribute

Description

Type

Unit

Name

User-friendly name of the current system profile

String

 

ProfileId

The profile Id of the current system profile

Integer

 

Reported

Time and date that the status was last reported

DateTime



Area Summary Element

The area summary element contains a list of Area Status elements. Each status element contains details on the area, including the user Id, name current state. When requesting a status report using a Command Message, the report can be filtered to only include the Area Summary Status.

Attribute

Description

Type

Unit

Reported

Time and date that the status was last reported

DateTime

 

Area Status Element

Attribute

Description

Type

Unit

Type

The type of area. These map to the area types in Witness:

General

Detection

Exclusion

Camera

Alarm

Static Target Detection

AreaTypeList

 

Name

The user friendly name of the area

String

 

AreaId

The User Id for the area

Integer



Enabled

The current state of the area. Depending on the type of area, the state has different implications. For example, disabling an Alarm area means it cannot be used inside rules. If a Detection areas is disabled it means the tracker will not generate tracks in that area. Disabling an exclusion area will stop it excluding data from the tracker allowing it to generate tracks

Boolean

 


Related Information

 

Safety is everything.