Changing Profiles
To find available profiles and change between different System Profiles, you can use either use the Profile shortcut or go through the System Menu.
Shortcut
- Find the Profile button in the top right hand corner of the UI, and select the current profile - in this example, Default.
- Use the Profile drop down to select a new profile.
- Select OK to save, and change profiles.
System Menu
- Go to System Menu>Settings>System Settings>System Profiles.
- Available profiles are listed in the System Profiles table.
- In Edit mode, select a profile from the Current Profile Name dropdown, then select Save. The System Profile has now changed.
Adding a New Profile
By default, there is only one System Profile: the Default profile. This profile has no values, therefore no global delta change to the Tracking Parameters' Settings.
To add a new profile:
- Go to System Menu>Settings>System Settings>System Profiles.
- In Edit mode, select the Add System Profile button .
- The Add System Profile window will open. Name and ID your profile. Select OK.
- The new profile will appear in the System Profiles table. Select Save. Currently, it will be as blank as a Default profile, so you must next configure the profile.
Configuring a Tracking Parameter Profile
- Enable the Config Function, then select a Tracking Parameter in the Configuration Tree.
- In the Configuration Panel, select Profiles.
- A new window, Tracking Parameter Profiles, will appear.
- If no profile has as yet been added, the table will be empty, because the Default profile does not appear, as it is locked from configuration. Default values will always be 0.
- However, in this example, we have added a new profile. Select New Profile in the table, then select Add.
- The Tracking Parameter Profile delta options will appear. Input your global delta changes.
- Plot Amplitude ATI (pwr): 2
- Plot Amplitude Track (pwr): 4
- Min Plot Azimuth Size (°): 1
- Min Plot Range Size (m): 1
- Min Plot Weight ATI (cells): 5
- Coasts (hits): 4
- Clutter Hold Multiplier: 2
- Max. Tracking Speed (m/s): 0
- Min.Tracking Speed (m/s): 1For example, below, if New Profile is the current profile, then this Tracking Parameter, Highways Debris, will actually use these settings:
- Select Save.
Related information
-
ClearWay™ System Design (Witness 4.0)
-
ICD-001 System Profile Command (Witness 4.0)
-
Exclusion Areas (Witness 4.0)
-
Detection Areas (Witness 4.0)
-
Live Tracks (Witness 4.0)
-
Creating a Detection Area (Witness 4.0)
-
AdvanceGuard® System Design (Witness 4.0)
-
System Design (Witness 4.0)
-
ClearWay™ Alarm Panel (Witness 4.0)
-
Database Configuration (Witness 4.0)
-
System Alarm Queries (Witness 4.0)
-
Configuration (Witness 4.0)
-
System Profiles (Witness 4.0)
-
Sea360® System Design (Witness 4.0)
-
ATI (Witness 4.0)