Introduction
This page covers the SafeGuard™ Configuration Application Navigation Data.
Contents
Navigation Data
The Navigation Data tab will only display data when requested by the user clicking the Snapshot and Pause Data button.
Bearing (°): The determination of the direction of the plot.
Range (m): This is the area of coverage of the plot.
Power (dB): The power amplitude of the plot.
Snapshot and Pause Data: Clicking this button will take a snapshot of the last rotation of NavMode data and show it on the PPI, thus pausing the live display.
Resume Data: This option resumes the live display of data on the PPI. This option is only enabled if there is no data coming from the radar.
Save Data to File: This option allows you to export the to a CSV file.
Load Background Image: Clicking this button will load in a Bitmap representing? radar range & plot on Background.
Clear Background: Click this button to remove and FFT or Bitmap from background of LHS - will this still be here?
Alarm Areas Only: When this checkbox is selected, only NewMode Output within the alarm areas is shown in the list and on the PPI. Always updating list of NavMode output. This list can be sorted by clicking the header.
Related Information
-
Adding a Relay Device (Industrial Automation)
-
Configuring Areas (Industrial Automation)
-
Quick Setup Guide (Industrial Automation)
-
Area Settings (Industrial Automation)
-
Configuration Options (Industrial Automation)
-
Starting SafeGuard™ (Industrial Automation)
-
Requirements (Industrial Automation)
-
PPI Display (Industrial Automation)
-
Radar Point Data (Industrial Automation)
-
Application Settings (Industrial Automation)