RAS6 - Radar Wiring Detail
Detail below defines the wiring connection to the Radar unit.
Refer to the separate configuration sheet for network settings.
Dust cap must always be fitted to ensure the integrity of the unit.
Pressure Valve – do not remove.
Earth point – M5x10 thread – to suitable earth grounding point
Radar Power Connector - D38999/24ZC8SN
Radar Data Connector - D38999/24ZB35SN
External Power Cable (WIR0114/05 – 5m)
Connector A - D38999/26ZC8PN
PINOUT TABLE | |||
---|---|---|---|
CON A | DESCRIPTION | DESTINATION | ALTERNATE |
C | 24V | RED | WHITE |
G | GND | BLACK | WHITE/BLUE |
D | 24V | WHITE | WHITE/ORANGE |
H | GND | BLUE | WHITE/GREEN |
External Data Cable (WIR0122/05 – 5m)
Connector A - D38999/26ZB35PN
PINOUT TABLE | ||
---|---|---|
CON A |
| CON B |
1 | WHITE/ORANGE | 1 |
2 | ORANGE | 2 |
3 | WHITE/GREEN | 3 |
4 | BLUE | 4 |
5 | WHITE/BLUE | 5 |
6 | GREEN | 6 |
7 | WHITE/BROWN | 7 |
8 | BROWN | 8 |
SCREEN |
| SHELL |
Next:RAS6 - Factory Acceptance Test
RAS6 Docs Home:RAS6 - Radar Documentation