Version 3.19.0 Build 1037 - 24 January 2019

Fixes:

  • WIT-2970 - Fixed speed rule to avoid all alarms being cleared  for a specific rule if one section went into queue


Note
titleSpeed Rule (SVD and Debris)

Prior to build 1037 any section going into queue with a stopped vehicle present would have cleared the same alarm for ALL sections. So the previous logic would have suppressed alarms or cleared them quicker. This would have manifested itself as alarms activating and deactivating in a short period time (i.e. less than the alarm timeout period). The fix will now leave alarms active for a given rule in all sections until they timeout because there are no more tracks breaking the rule. This should not make any noticeable change although the old logic may have been more aggressive at suppressing unwanted alarms.

Version 3.19.0 Build 1034 - 21 January 2019

Fixes:

  • Change Temperature to be a short to match the specification
  • Fix Correlation not updating last seen when handling tracks
  • Updated ICD-005 alarm report to include the ping time alarm type. Previously this was reported only as a rotation issue 

Version 3.19.0 Build 1025 - 19 April 2018

Fixes:

  • Fixed average calculation in Count Classify

New Features:

  • Area Covered logic added to numeric properties of rules

Experimental:

  • Added support for AXIS Q8641-E
  • Added Dallmeier TopLine S8 camera model

Download release from: /wiki/spaces/WIT/pages/1572901


...