  1. Remove all four of the small captive retaining bolts from the top assembly and replace them with the new ones provided within the service kit.

    It is important to replace these bolts at each service interval because their hex key recesses are easily weakened when the top assembly is removed, due to the Loctite applied to the threads.
  2. Once the new bolts are in place, apply Loctite 243 to their threads.
  3. Align the top assembly with the turntable. Ensure that the alignment tab of the top assembly is correctly aligned with the cutaway of the turntable rotor.
  4. Using a 2.5mm hex key (do not use ball ended drivers), tighten the bolts evenly to a torque of 80~100cNm). Do NOT over tighten.
  5. Check that the top assembly on the turntable can rotate freely.