Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


The heartbeat report is a simple empty content message that can be used to identify whether the Witness server is online and operational. This is also used to check the connection status to all the clients. In the event that the heartbeat fails to send to a specific client then the connection to that client will be terminated.

The heartbeat interval can be configured as part of the ICD-001 plugin configuration on the Witness server.


Panel
borderColorsilver
borderWidth1

On this page:

Table of Contents
maxLevel3
indent10px

The heartbeat interval can be configured as part of the ICD-001 plugin configuration on the Witness server.


Info

The heartbeat is simply the 10 byte header with no payload. The payload length value in the header must be set to 0 (zero).

Client Heartbeats

Heartbeats can be sent from the clients. This is recommended because it provides a robust method to ensure the client to server connection is still alive. The format for the heartbeat is exactly the same - header only.