Info |
---|
NOTE: Radars are network intensive. Some laptops reduce the performance of their network connection when only running on their internal battery. |
The following are essential additional items that you need to install a radar sensor:
- Electrical Power
Electrical power (110 to 230vAC) sourced from, for example, local mains.
110 to 230vAC power is required for the Radar's 24vDC PSU.
110 to 230vAC power is also required for the Laptop Computer used during the commissioning process.
- Laptop computer
The laptop should have:
- RJ45 Ethernet connection.
- 9 pin Com port or USB to RS232 adapter [Optional]
- Software – SPxRadarViewLite-V1.59.3 or higher, with correct configuration file
- Web Browser (IE v10 or higher, Chrome)
- Cat5E shielded patch lead (or Cross over cable, if laptop doesn't have Auto-MDIX)
- M10 nuts and bolts for mounting radar
The minimum for one radar is, in :
- Bolt fixings pack supplied with the radar including:
- x8 off M8 bolts A4 Stainless Steel
- x4 off
- M8 spring washers A4 Stainless Steel
- x4 off
- x4 off Nyloc Nuts
- x12 off M10 Full plain nuts
- x2 off 17mm Spanner for the M10 nuts and bolts above.
- M8 plain washers A4 Stainless Steel
- x1 off Mount plate and mounting fixings (refer to Installation section to see examples, this will depend on your mounting choice)
- x1 M5 bolt
- Suitable earthing cable to fit to M5 bolt hole
- 5m tape measure
- A Digital Inclinometer (accurate to 0.1°)
- x2 off 25m² Radar Target (Navtech part number MBP0137)
- x2 off Tripod for mounting Radar Target (Optional, this requirement will vary depending on application)
- Pair of 2 way radios
- Adjustable spanners
- An assistant
- A suitable Radar Power Supply cable (supplied with Radar)
- A way of working safely at height
Power Supply Details
- Siemens Part Number: 6EP1332-1SH52
- 24V Stabilised Power Supply
- Input 100-240V AC
- Output 24V / 4A DC.
- Dimensions: 55mm x 90mm x 90mm
- Will snap to DIN rail EN 60715 35x7.5/15