The configuration in Witness AdvanceGuard® is also included.

Contents

...

Table of Contents
maxLevel3
indent16px
excludeIntroduction|Contents

...

Enable PTZ Control

  1. For ONVIF cameras you need to ensure that PTZ is enabled as Absolute in the server settings:

...

  1. Image Added

Configuring PTZ Control via SDK in Milestone

  1. A "Basic User” needs to be configured:

...

  1. Image Added

  2. This new Basic User requires a security role (in this example it’s called “WitnessRole”), with the at least the Read, View Live, Aux Commands and PTZ Camera permissions selected:

...

  1. Image Added

  2. The PTZ priority must be enabled the on the camera group:

...

  1. Image Added

Witness VMS Camera Control Configuration

In order to control the cameras within Milestone via the AdvanceGuard® UIWitness UI™, you will need to configure the same user for both in AdvanceGuard®:

  1. In the Configuration Tree in the Live screen, select the Milestone Plugin which is under Integration Configurations. This will display the Milestone Plugin information on the right-hand-side. Click Edit:

...

  1. Image Added

  2. Then ensure that the Milestone Plugin is enabled, and that the Milestone Server IP address is correctly entered, and the User Name is the same as entered into the Milestone services. Save the configuration:

...

  1. Image Added

  2. Next select the VMS Camera Control branch and click New:

...

  1. Image Added

  2. Then select Milestone Configuration:

...

  1. Image Added

  2. This will open the Create New Milestone Configuration wizard. Select Finish:

...

  1. Image Added

  2. Enter the Milestone Server IP Address, along with the same User Name as in step 2, and click Save:

...

  1. Image Added

  2. Then configure a camera to use Milestone Camera Control; there is a drop down option to select Direct Control (ONVIF) or the Milestone connection:

...

  1. Image Added

  2. ​Select the Milestone option. There is a Link Camera option. The Link Camera icon button will be displayed in red as no camera have yet been linked:

...

  1. Image Added

  2. Selecting the Link Camera option opens a list of cameras on the Milestone system. Select a camera on the list to assign the camera in AdvanceGuard®:

...

  1. Image Added

  2. Once the camera has been linked, the Link Camera button turns white:

...

  1. Image Added

  2. Once the configuration has been saved, the External ID will be displayed in the Advanced tab:

...

  1. Image Added

Note

If the camera is not assigned to a controller or the camera controller is not running the link will not show any cameras.