Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Tip

The plugin can be selected during setup and will automatically be installed in the correct location.

Installing the CAT-10 Plugin Plugin

When installing AdvanceGuard®, in the Choose Components page of the AdvanceGuard® Setup wizard, open Integration Plugin options and select CAT 10:

...

Configuring the CAT-10 Plugin in AdvanceGuard®

When the plugin is installed and licensed, a plugin configuration with default settings is automatically generatedThe CAT-10 Plugin will appear as a node under the Integration Configurations folder within the Configuration Tree. The settings can be viewed and edited by enabling the Config Function, then selecting the plugin in Integration Configurations, within the Configuration Tree. Configuration settings will then be available in the Configuration Panel. 

...

CAT-10 Original Specification

8

7

6

5

4

3

2

1

SPI

0

0

0

0

0

0

FX

SPI: Special Position Identification

...

Witness CAT-10 repurposed specification

8

7

6

5

4

3

2

1

SPI

Classification

FX

Classification: 6 bit unsigned integer (0-32) indicating the classification:

Bit Representation

Numeric Value

Classification

Byte Value

000001

1

Any

2

000010

2

Unclassified

4

000011

3

Person

6

000100

4

Debris

8

000101

5

Boat

10

000110

6

Vehicle

12

000111

7

Aeroplane

14

001000

8

Helicopter

16

Vehicle and Aeroplane classifications can also be obtained from the standard Target Report Descriptor First Extent as per CAT-10 specifications.

...

Filter by label (Content by label)