Introduction

OPC United Architechture Architecture (OPC UA) protocol is widely used industrial communications protocol. The ICD-007 OPC Server integration plugin instantiates an OPC UA Server within the Witness system, allowing 3rd party OPC UA clients to connect and obtain data from. The OPC UA Specifications come in multiple parts and can be obtained from the OPC Foundation website.

...

Status Codes for the health value of the Radar/s, Management Server/s and Track Engine/s:

Contents

...

Table of Contents
maxLevel3
indent16px
excludeIntroduction|Contents

...

The data is transmitted as the events occur, leading to near-real time reporting.

...

The

...

OPC Server

...

Plugin

...

...

The

...

When installing Witness , in the Choose Components page of the Witness Setup wizard, open Integration Plugin options and select ICD007:

...

The OPC Server Plugin

The Witness system supports integration with many different types of external systems through the use of plugins. These are stand-alone software libraries which are dynamically loaded by the Integration Manager and contain code which knows how to convert the Witness data into the required format for the external system. Navtech Radar can easily develop bespoke plugins to interface with a specific type of equipment or application. The OPC Server plugin has been developed to provide integration to the common OPC UA standard used in highway systems.The OPC Server plugin file is entitled Tungsten.Integration.ICD007.Plugin.dll and must be present in the Witness Plugin folder which is inside the main application folder. The plugin depends on OPC Foundation's liberaries Opc.Ua.Core.dll and Opc.Ua.Server.dll which must be present in the same folder.

OPC UA Client

...

Prerequisites

The OPC UA client used to connect to the OPC server must login through a Username and Password channel. Other authentication methods are not supported.

...

Configuring the OPC Server Plugin

When the plugin is installed and licensed, a plugin configuration with default settings is automatically generatedThe ICD-007 Plugin will appear as a node under the Integration Configurations folder within the Configuration Tree. The settings can be viewed and edited by enabling the Config Function, then selecting the plugin in Integration Configurations, within the Configuration Tree. Configuration settings will then be available in the Configuration Panel. 

...

Info

Once you have made changes to the plugin configuration and committed the changes by saving, the plugin will automatically rebuilt itself based on the new configuration.

The setting options are as follows:

...

Windows: Default - tries to read the certificate from in Windows Certificate Store. Certificate path must be a valid windows certificate store path e.g. "CurrentUser\My" or "LocalMachine\TrustedPublisher".

Directory: This tries to read the certificate from the file storage.

The subject name of the certificate must match the DNS name of the machine the OPC Server is run on.

Certificate Path: Location to store the server certificate. This can be a file location e.g. "C:\OpcCertificate\" if using Directory certificate type or Certificate Store path e.g. "CurrentUser\My"

...

Carriageways: This section indicates the carriageways that we want to track in the OPC server. When a highway alarm is received, only an alarm matching a configured Carriageway will be processed.

Select

Carriageway Name

Select this to track carriageway the OPC server.

The carriageway you wish to track.

Warning

If Certificate Type is "Directory", auto create certificate can only create new certificates if OPC Foundation Redistributable is installed.

If the specified certificate does not exist and new certificate cannot be created (e.g. due to the above or if Auto create Certificate is not selected), the plugin will not be able to start up.

...

Each node is listed first with Display Name, DataType and namespace : relative browse name. Child nodes are indented relative to their parent.

Witness

Folder

1:Witness







Heartbeat

Int32

1:Heartbeat





ManagementServerHealth

Int32

1:ManagementServerHealth





TrackEngineHealth

Int32

1:TrackEngineHealth





DatabaseHealth

Int32

1:DatabaseHealth





CarriagewayCount

Int32

1:CarriagewayCount





RadarCount

Int32

1:RadarCount





CarriageWays

Folder

1:CarriageWays






Carriageway 1

Folder

1:Carriageway1






SectionCount

Int32

1:SectionCount





Section 1

Folder

1:Section1






SectionId

Int32

1:SectionId





Mode

Int32

1:Mode






RadarId

Int32

1:RadarId






TrafficData

Boolean

1:TrafficData





AverageSpeed

Double

1:AverageSpeed





AverageCount

Int32

1:AverageCount





Reversing Rule

Folder

1:Rule1







Description

String

1:Description






Active

Boolean

1:Active






Raised

DateTime

1:Raised






LocationX

Double

1:LocationX






LocationY

Double

1:LocationY






Lane

Int32

1:Lane





Speed Rule

Folder

1:Rule2







Description

String

1:Description






Active

Boolean

1:Active






Raised

DateTime

1:Raised






LocationX

Double

1:LocationX






LocationY

Double

1:LocationY






Lane

Int32

1:Lane




Section 2

Folder

1:Section2






SectionId

Int32

1:SectionId





Mode

Int32

1:Mode






RadarId

Int32

1:RadarId






TrafficData

Boolean

1:TrafficData





AverageSpeed

Double

1:AverageSpeed





AverageCount

Int32

1:AverageCount





Reversing Rule

Folder

1:Rule1







Description

String

1:Description






Active

Boolean

1:Active






Raised

DateTime

1:Raised






LocationX

Double

1:LocationX






LocationY

Double

1:LocationY






Lane

Int32

1:Lane





Speed Rule

Folder

1:Rule2







Description

String

1:Description






Active

Boolean

1:Active






Raised

DateTime

1:Raised






LocationX

Double

1:LocationX






LocationY

Double

1:LocationY






Lane

Int32

1:Lane





Person Rule

Folder

1:Rule3







Description

String

1:Description






Active

Boolean

1:Active






Raised

DateTime

1:Raised






LocationX

Double

1:LocationX






LocationY

Double

1:LocationY






Lane

Int32

1:Lane


Sensors

Folder

1:Sensors







Radar 1

Folder

1:Sensor7083798e-329d-4eb6-a4bc-4dee3553faea




LastHealth

Int32

1:LastHealth





LastTime

DateTime

1:LastTime





RadarId

Int32

1:RadarId





Radar 2

Folder

1:Sensord8aec3b1-4f71-41c1-8d90-0bb0387340b0




LastHealth

Int32

1:LastHealth





LastTime

DateTime

1:LastTime





RadarId

Int32

1:RadarId




README

String

1:README




OPC Login Credentials

...

To log in to the OPC server with an OPC client, you can use the credential of any System user. If none exist, an admin level user may create a new one.

...