Using SPx RadarView Lite
The SPx RadarView application consists of two files which must be located in the same folder (any folder) on your laptop:
...
- Run SPXRadarView.exe. You should see a blank main screen:
Note: In the lower panel, the Video and Turn indicators will be red indicating that there is no communication with the sensor
- Click the Channel-A menu on the toolbar, and select the Source... option.
...
- Repeat steps 5 and 6 for the other target so that you can view both on screen at the same time.
- Adjust the radar sensor level (See Section 2.7) while checking the scan graphs to ensure the best response from both targets.
- To assist with orientation, optionally click the button to show the Graphics Control dialog box:
...
- Enable the Compass Ring option to superimpose compass graduation marks around the sensor view.
Note: North is aligned to the zero point of the radar sensor, not magnetic north.
- Enable the Range Rings option to overlay range lines every 100m onto the sensor view
Specifications
...
Radar power cable
...
318-B LSZH cable
...
...
Part no
...
Eland A5Z02015BK
...
No of Cores x Nominal Cross Sectional Area
...
2 x 1.5 mm2
...
Core Identification
...
2 cores: Blue, Brown
...
Current carrying capacity
...
Single phase AC 16 amps
...
Insulation
...
LSZH ( application dependent )
...
Sheath
...
LSZH ( application dependent )
...
Standard
...
IEC 60092-353
...
Conductor
...
Class 5 flexible plain copper to BSN EN 60228:2005
Radar Cat 5E cable
...
Cat 5E cable
...
...
Part no
...
Eland A8NCAT5EFTPGSWB
...
No of pairs
...
4
...
Core Identification
...
4 pairs: Blue + White/Blue, Orange + White/Orange, Green + White/Green, Brown + White/Brown
...
Standards
...
ISO/IEC 11801, TIA/EIA 568B
...
Braiding
...
GSWB (Galvanised Steel Wire Braid)
...
Sheath
...
LSZH ( application dependent )
...
Sheath colour
...
Black
Radar Cat 5E Ethernet cable specification
- Radar power cable connector (radar end)
...
Amphenol 97 series
...
...
MIL Spec
...
MIL-C-50152
...
Model
...
3106A
...
Operating temperatures
...
–55°C to +125°C
...
Power pins
...
Pin D (Red or Brown wire) & Pin J (Blue or Black wire)
...
Design Characteristics
...
10 socket plug, Single key/keyway polarization Threaded coupling, hard dielectric inserts
Radar power cable (radar end) connector specification
- Radar Cat 5E cable connector (radar end)
...
Amphenol RJF series
...
...
Part No
...
RJF6
...
MIL Spec
...
MIL-C-26482
...
Data Transmission
...
Category 5e per ISO/IEC 11801
...
Mechanical
...
Bayonet coupling (Audible & Visual coupling signal)
4 mechanical Coding / Polarization possibilities by the user (insert rotation)
RJ45 cordset retention in the plug : 100 N in the axis Mating cycles : 500 min
...
Environmental Protection
...
Sealing: IP67
Salt Spray : 48 h with Nickel plating> 96 h with black coating> 500 h with hard anodic coating and Cadmium
Fire /Low Smoke: UL94 V0 and NF F 16 101 & 16 102
Vibrations : 25 –250 Hz, 5 g, 3 axes : no discontinuity> 1μs Humidity: 21 days, 43°C, 98%humidity
Rapid change of Temperature: 5 –20°C / +85°C cycles
Radar Cat 5E cable connector (radar end) specification
Construction of test target
...
Back of target. The lower piece can overlap on to the back of the target to ease production and increase strength
Welded on nuts are: ¼ Whitworth and 5/8th UNC stainless nuts.
Radar sensor configurations
A sample table to record data for each radar.
...
Radar Sensor
...
Serial No
...
IP Address
...
Subnet Mask
...
GPS position
Lat(N)
...
Long (E)
...
Radar Base Plate Angle
(deg)
...
Example
...
100
...
192.168.1.170
...
255.255.255.0
...
59.25023
...
17.85109
...
+1.5
...
A1
...
...
...
...
...
...
...
A2
...
...
...
...
...
...
...
A3
...
...
...
...
...
...
...
A4
...
...
...
...
...
...
Outline System Diagram
Radio Frequency Energy Compliance
...
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
...
Installing in Harsh Environments
Chesterton© 740 Aerosol Application to I-Series Radar Connectors on Installation
...
Health & Safety
...
- Attach the power and data connectors to the radar. Checking their surfaces are free from dirt, oil, grease and moisture.
- If the radar has a vent plug attached temporarily cover or mask the vent so that when spraying the connectors no spray enters the vent plug.
- Evenly apply the spray to the connectors. Observing the Health and Safety guidelines while doing so.
- While drying residual product can be removed with a cloth. After drying a degreaser can be used to remove the product.
...
Next: Radar configuration record & system diagram