The ICD-001 Alarm Load Simulator provides ClearWay™ carriageway alarms over the ICD-001 interface that are recorded within the databaseraised as normal alarms. There are two types of alarms - short and long alarms. These stopped vehicle alarms will be raised with the same information as a genuine alarm and cleared at random periods depending on the configuration of the system. The simulation can be run using a batch file on an external machine.

...

This allows you to configure individual cycles which have a cycle length that can be set in minutes.

CarriagewaysCycleLength: Enter This sets the name length of the carriageway you wish to use for the simulation.CycleLength: This sets the length of the cycle in minutescycle in minutes.

Carriageways: This allows you to configure individual carriageways for the cycle.

Name: This sets which carriageway will use the following configuration for the alarms.

EmergencyAreaAlarms: This sets the alarm values for the emergency areas (Lane 0). If this is not set, Lane 0 is assumed to be a live lane.

...

  1. Once you have configured the AlarmLoadSimulatorTestConfig.xml file, start the Track Engine.

  2. The system will perform each cycle in order before looping back to the first one.

  3. Each cycle can have one or more carriageways specified and each carriageway can have ERA alarms and live lane alarms configured with an alarm rate (alarms/hour) and the percentage of alarms raised that will be short alarms.

  4. It should start automatically, generating alarms for the carriageways based on the current test cycle.

  5. It picks a random section and lane for live lane alarms when there are more lanes configured.

  6. If you use ICD-001 to receive alarm reports, you should get alarm reports through once it starts raising the alarms. Please refer to ICD-001 Alarm Report for more information.

  7. Stopping the Track Engine will stop the simulation.

  8. The configuration will not be able to be changed whilst running a simulation. To update the configuration you will need to stop the Track Engine, amend the config file and then restart the Track Engine.

  9. For a simple evaluation of the alarms you can use the alarm query feature on the playback tab. For more information please refer to:https://navtechradar.atlassian.net/wiki/spaces/TUN/pages/236748943/Alarm+Queries#Alarm-Query.

...