Introduction
This page covers the ICD-001 External Trigger Command.
Contents
...
Table of Contents | ||||||
---|---|---|---|---|---|---|
|
...
External Trigger Command Attributes
Attributes | Description | Type | Notes |
MsgId | Unique message Id | Long | This must be globally unique across all message types |
MsgTimeStamp | Date and time that the message was sent | DateTime | |
TriggerId
| Id of the external trigger | Integer |
|
Enable | Desired state of the trigger | Boolean | This is the state that needs to be applied to the trigger. Actions can be configured in Witness to respond to either the true or false state. True = Enable, False = Disable |
Timeout* | Optional attribute that provides the option to reverse a state once the timeout has expired | Integer | Timeout is in seconds |
Network Sender Element
Each incoming message can include an optional Sender element. This must include the IP address and port that the client is using to send instructions.
...