The update entity command provides the ability to change the enabled status of any Witness entity, for example, alarm zones and detection areas. The command uses the numeric User Id to identify the entity to change and sets the state through the Enabled attribute. Each entity will respond slightly differently when their state is changed. For example, when an alarm zone is disabled, it stops raising alarms associated with the area, however when a detection area is disabled it will stop tracking in this area.

...

Info

Please note the following:

  • The entity is located based on the entity type and the User Id, therefore the combination of these two types values must be unique. The configured User Id values must be unique within their given each entity type group, however this means they can be duplicated across different entity types

  • Areas must be configured with a Disarm Mode of Automatic to be enabled or disabled this update command.

...