Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The Witness system supports integration with many different types of external systems through the use of plugins. These are stand-alone software libraries which are dynamically loaded by the Integration Manager and contain code which knows how to convert the Witness data into the required format for the external system. Navtech Radar can easily develop bespoke plugins to interface with a specific type of equipment or application. The OPC Server plugin has been developed to provide integration to the common OPC UA standard used in highway systems.

Installing the OPC Server Plugin

...

OPC

...

Tip

The plugin can be selected during setup and required files will automatically be installed in the correct location.

When installing Witness, in the Choose Components page of the Witness Setup wizard, open Integration Plugin options and select ICD007:

...

UA Client Prerequisites

The OPC UA client used to connect to the OPC server must login through a Username and Password channel. Other authentication methods are not supported.

...

Configuring the OPC Server Plugin

When the plugin is installed and licensed, a plugin configuration with default settings is automatically generated. The settings can be viewed and edited by enabling the Config Function, then selecting the plugin in Integration Configurations, within the Configuration Tree. Configuration settings will then be available in the Configuration Panel. 

...

Carriageways: This section indicates the carriageways that we want to track in the OPC server. When a highway alarm is received, only an alarm matching a configured Carriageway will be processed.

Select

Carriageway Name

Select this to track carriageway the OPC server.

The carriageway you wish to track.

Warning

If Certificate Type is "Directory", auto create certificate can only create new certificates if OPC Foundation Redistributable is installed.

If the specified certificate does not exist and new certificate cannot be created (e.g. due to the above or if Auto create Certificate is not selected), the plugin will not be able to start up.

...

Each node is listed first with Display Name, DataType and namespace : relative browse name. Child nodes are indented relative to their parent.

Witness

Folder

1:Witness







Heartbeat

Int32

1:Heartbeat





ManagementServerHealth

Int32

1:ManagementServerHealth





TrackEngineHealth

Int32

1:TrackEngineHealth





DatabaseHealth

Int32

1:DatabaseHealth





CarriagewayCount

Int32

1:CarriagewayCount





RadarCount

Int32

1:RadarCount





CarriageWays

Folder

1:CarriageWays






Carriageway 1

Folder

1:Carriageway1






SectionCount

Int32

1:SectionCount





Section 1

Folder

1:Section1






SectionId

Int32

1:SectionId





Mode

Int32

1:Mode






RadarId

Int32

1:RadarId






TrafficData

Boolean

1:TrafficData





AverageSpeed

Double

1:AverageSpeed





AverageCount

Int32

1:AverageCount





Reversing Rule

Folder

1:Rule1







Description

String

1:Description






Active

Boolean

1:Active






Raised

DateTime

1:Raised






LocationX

Double

1:LocationX






LocationY

Double

1:LocationY






Lane

Int32

1:Lane





Speed Rule

Folder

1:Rule2







Description

String

1:Description






Active

Boolean

1:Active






Raised

DateTime

1:Raised






LocationX

Double

1:LocationX






LocationY

Double

1:LocationY






Lane

Int32

1:Lane




Section 2

Folder

1:Section2






SectionId

Int32

1:SectionId





Mode

Int32

1:Mode






RadarId

Int32

1:RadarId






TrafficData

Boolean

1:TrafficData





AverageSpeed

Double

1:AverageSpeed





AverageCount

Int32

1:AverageCount





Reversing Rule

Folder

1:Rule1







Description

String

1:Description






Active

Boolean

1:Active






Raised

DateTime

1:Raised






LocationX

Double

1:LocationX






LocationY

Double

1:LocationY






Lane

Int32

1:Lane





Speed Rule

Folder

1:Rule2







Description

String

1:Description






Active

Boolean

1:Active






Raised

DateTime

1:Raised






LocationX

Double

1:LocationX






LocationY

Double

1:LocationY






Lane

Int32

1:Lane





Person Rule

Folder

1:Rule3







Description

String

1:Description






Active

Boolean

1:Active






Raised

DateTime

1:Raised






LocationX

Double

1:LocationX






LocationY

Double

1:LocationY






Lane

Int32

1:Lane


Sensors

Folder

1:Sensors







Radar 1

Folder

1:Sensor7083798e-329d-4eb6-a4bc-4dee3553faea




LastHealth

Int32

1:LastHealth





LastTime

DateTime

1:LastTime





RadarId

Int32

1:RadarId





Radar 2

Folder

1:Sensord8aec3b1-4f71-41c1-8d90-0bb0387340b0




LastHealth

Int32

1:LastHealth





LastTime

DateTime

1:LastTime





RadarId

Int32

1:RadarId




README

String

1:README




OPC Login Credentials

...

To log in to the OPC server with an OPC client, you can use the credential of any System user. If none exist, an admin level user may create a new one.

...