Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Pressure Valve – do not remove.

  2. Earth point – M5x10 thread – to suitable earth grounding point

  3. Radar Power Connector - D38999/24ZC8SN

  4. Radar Data Connector - D38999/24ZB35SN

...

External Power Cable (WIR0114/05 – 5m)

Connector A - D38999/26ZC8PN

...

...

PINOUT TABLE

CON A

DESCRIPTION

DESTINATION

ALTERNATE

C

24V

RED

WHITE

G

GND

BLACK

WHITE/BLUE

D

24V

WHITE

WHITE/ORANGE

H

GND

BLUE

WHITE/GREEN

External Data Cable (WIR0122/05 – 5m)

Connector A - D38999/26ZB35PN

...

PINOUT TABLE

CON A

CON B

1

WHITE/ORANGE

1

2

ORANGE

2

3

WHITE/GREEN

3

4

BLUE

4

5

WHITE/BLUE

5

6

GREEN

6

7

WHITE/BROWN

7

8

BROWN

8

SCREEN
(SECURE TO ITEM 7)

SHELL