Health Timer: Interval, in seconds, at which the heartbeat counter on the OPC Server will count up while it is connected to the Witness system. This can be used to monitor the overall health of the OPC Server plugin.
Primary MS IP: The IP address of the primary Management Server. This is incorporated into the certificate.
Secondary MS IP: The IP address of the secondary Management Server. This is also incorporated into the certificate in case of failover.
Port: The port used for the OPC communication. By default this is 51210.
Plugin Application Name: Application Name reported through the OPC protocol. This should have the same URI as the security certificate.
...
Write node structure to CSV: With this option selected the plugin will write out the OPC node structure for the current configuration into a CSV file every time it starts. The file will be saved in %ProgramData%\Navtech\OPCServer folder.
Use Anonymous Login: This allows clients to connect anonymously without using a username and password. This is not recommended other than for testing or for use with systems which don’t support proper authentication.
Carriageways: This section indicates the carriageways that we want to track in the OPC server. When a highway alarm is received, only an alarm matching a configured Carriageway will be processed.
Select | Carriageway Name |
---|---|
Select this to track carriageway the OPC server. | The carriageway you wish to track. |
...